I want to download my linux image to Xilinx ML403 board using the download script provided in the Microblaze-Tutorial from John Williams.
No target with id: -1. Use command "targets" to get target list
Error: Invalid xmd target: -1
Use "targets" command to get current list of targets or change target
Use "connect mb" command to connect to a MicroBlaze target
Use "connect ppc" command to connect to a PowerPC target
I didn't find anything about the invalid target-id, and I did not find any
Correspondig -1 in the download script.
Any ideas?
I did not update opb_mdm to Version 2.01a since i have XCFX12-FF668-10 (not V4LX25 ES)
Philipp
$ ./dl.sh
Kimage is binaries/image.bin
Kparams are
Xilinx Microprocessor Debug (XMD) Engine
Xilinx EDK 8.2 Build EDK_Im.14
Copyright (c) 1995-2005 Xilinx, Inc. All rights reserved.
XMD%
XMD% Loading MHS File..
Processor(s) in System ::
Microblaze(1) : microblaze_0
Address Map for Processor microblaze_0
(0x00000000-0x00001fff) dlmb_cntlr dlmb
(0x00000000-0x00001fff) ilmb_cntlr ilmb
(0x28000000-0x2bffffff) DDR_SDRAM_64Mx32 mb_opb
(0x2c000000-0x2c7fffff) FLASH_2Mx32 mb_opb
(0x40600000-0x4060ffff) RS232_Uart mb_opb
(0x41200000-0x4120ffff) opb_intc_0 mb_opb
(0x41400000-0x4140ffff) debug_module mb_opb
(0x41c00000-0x41c0ffff) opb_timer_1 mb_opb
XMD% Connecting to cable (Parallel Port - LPT1).
Checking cable driver.
Driver windrvr6.sys version = 7.0.0.0. LPT base address = 0378h.
ECP base address = 0778h.
Cable connection failed.
Connecting to cable (Parallel Port - LPT1).
Checking cable driver.
Driver windrvr6.sys version = 7.0.0.0. LPT base address = 0378h.
ECP base address = 0778h.
Cable connection failed.
Connecting to cable (Parallel Port - LPT2).
Checking cable driver.
Driver windrvr6.sys version = 7.0.0.0.Cable connection failed.
Connecting to cable (Parallel Port - LPT2).
Checking cable driver.
Driver windrvr6.sys version = 7.0.0.0.Cable connection failed.
Connecting to cable (Usb Port - USB22).
Checking cable driver.
Driver xusbdfwu.sys version: 1021 (1021).
Driver windrvr6.sys version = 7.0.0.0.Calling setinterface num=0, alternate=0.
DeviceAttach: received and accepted attach for:
vendor id 0x3fd, product id 0x8, device handle 0x2930038
Cable PID = 0008.
Max current requested during enumeration is 280 mA.
Cable Type = 3, Revision = 0.
Setting cable speed to 6 MHz.
Cable connection established.
Firmware version = 1021.
CPLD file version = 0012h.
CPLD version = 0012h.
JTAG chain configuration
--------------------------------------------------
Device ID Code IR Length Part Name
1 0a001093 8 System_ACE
2 05059093 16 XCF32P
3 01e58093 10 XC4VFX12
4 09608093 8 xc95144xl
Assuming, Device No: 3 contains the MicroBlaze system
WARNING:MDT - MDM Peripheral Not Detected on Hardware
WARNING:MDT - Assuming opb_jtag_uart peripheral
Connected to the JTAG MicroProcessor Debug Module (MDM)
No of processors = 1
UNKNOWN Processor Version (0)
Verify if FPGA Bitstream was downloaded and DONE pin went High
XMD% Downloading kernel image...
XMD% This will only take a few seconds!
XMD%
No target with id: -1. Use command "targets" to get target list
Error: Invalid xmd target: -1
Use "targets" command to get current list of targets or change target
Use "connect mb" command to connect to a MicroBlaze target
Use "connect ppc" command to connect to a PowerPC target
XMD% XMD% setting kernel command line
XMD% XMD% "cmdline is "
XMD% 2
XMD% 0x100
XMD% > > > > XMD%
No target with id: -1. Use command "targets" to get target list
Error: Invalid xmd target: -1
Use "targets" command to get current list of targets or change target
Use "connect mb" command to connect to a MicroBlaze target
Use "connect ppc" command to connect to a PowerPC target
XMD%
No target with id: -1. Use command "targets" to get target list
Error: Invalid xmd target: -1
Use "targets" command to get current list of targets or change target
Use "connect mb" command to connect to a MicroBlaze target
Use "connect ppc" command to connect to a PowerPC target
XMD%
No target with id: -1. Use command "targets" to get target list
Error: Invalid xmd target: -1
Use "targets" command to get current list of targets or change target
Use "connect mb" command to connect to a MicroBlaze target
Use "connect ppc" command to connect to a PowerPC target
XMD%
No target with id: -1. Use command "targets" to get target list
Error: Invalid xmd target: -1
Use "targets" command to get current list of targets or change target
Use "connect mb" command to connect to a MicroBlaze target
Use "connect ppc" command to connect to a PowerPC target
XMD% Done already WOW!
XMD%